Tests

Type of test Testing Body       RESULT
Toxicological tests
Product biological assessment  Head Testing Centre of Hygiene Research Institute, Novosibirsk

Ceramic components are non-toxic, sterile, pyrogen-free, hemolytically neutral, and have no skin irritating effect. No sensitizing effect was found Meet all the requirements for medical devices

Characteristics determination of material degradation   Head Testing Centre of Hygiene Research Institute, Novosibirsk Samples after testing do not show degradation traces
Toxicological tests of medical product Head Testing Centre of Hygiene Research Institute, Novosibirsk

Meet all the requirements for medical devices

Toxicological tests of medical product

Laboratory of Cancer Research Center  for Quality Control, Moscow 

According to sanitary, chemical, cytotactic, irritant, toxic, genotoxic indicators, and the results of the implant test, product meet the requirements for medical devices. Confirmed sterility of the product

Toxicological tests of medical product Medical Technology Research and Testing Institute of Federal Service for Surveillance in Healthcare, Moscow Comply with safety requirements
Technical tests
Friction pair durability tests National Medical Research Center of Traumatology and Orthopedics N.N.Priorova, Moscow The durability of the product has been confirmed for at least 10 years
Strength characteristics Zimmer Biomet UK, Swindonm No signs of wear Samples tested exceeded the minimum requirements  for ceramic hip heads
Torque determination of friction pair with polyethylene lining CITOproject, Moscow The test results confirm the stated durability of the product. There are no signs of wear
Femoral head determination wear and tear for a full torque testing cycle of a friction pair with lining CITOproject, Moscow The test results confirm the stated durability of the product. There are no signs of wear
Compliance testing Testing Center «Medi-Technological Agency», Moscow The medical device fully compliant with regulations
Static compression tests Testing laboratory of the Research Center, Novosibirsk Akademcity The maximum load values exceed the established requirements
Clinical tests
Clinical tests Novosibirsk Research Institute of Traumatology and Orthopedics Y.L. Tsivyan Fully complies with all regulatory, technical and operational requirements announced by manufacturer for intended purpose and usage, quality, effectiveness and safety to use in clinical practice
Clinical tests National Medical Research Center of Traumatology and Orthopedics N.N.Priorova, Moscow Complies with all regulatory, technical and operational requirements and can be recommended for registration and subsequent use in medical institutions